Ultrasonic Flow Meters

20+ Years Manufacturing Experience

Transit-time Ultrasonic Flowmeter

  • Wall-mounted Transit-time Ultrasonic Flowmeter TF1100-EC

    Wall-mounted Transit-time Ultrasonic Flowmeter TF1100-EC

    TF1100-EC Wall-mounted Transit Time Ultrasonic Flowmeter works on the transit-time method. The clamp-on ultrasonic transducers (sensors) are mounted on the external surface of the pipe for non-invasive and non-intrusive flow measurement of liquid and liquefied gasses in fully filled pipe. Two pairs of transducers are sufficient to cover the most common pipe diameter ranges. In addition, its optional thermal energy measurement capability makes it possible to carry out a complete analysis of thermal energy usage in any facility.

    This flexible and easy to use flow meter is the ideal tool for the support of service and maintenance activities. It can also be used for the control or even for the temporary replacement of permanently installed meters.

  • Insertion Transit-time Ultrasonic Flowmeter TF1100-EI

    Insertion Transit-time Ultrasonic Flowmeter TF1100-EI

    TF1100-EI transit-time Insertion ultrasonic flowmeter provides abundant capabilities for accurate liquid flow measurement from outside of a pipe. It utilizes state-of-the-art technologies on ultrasonic transmission /receiving, digital signal processing and transit-time measurement. The proprietary signal quality tracking and self-adapting technologies allow system to optimally adapt to different pipe materials automatically. Due to hot-tapped mounting of insertion transducers, there is no ultrasonic compound and coupling problem; Even though the transducers are inserted into pipe wall, they do not intrude into the flow, thus, do not generate disturbance or pressure drop to the flow. The insertion (wetted) type has the advantage of long-term stability and better accuracy.

  • Portable Transit-time Clamp On Ultrasonic Flowmeter TF1100-EP

    Portable Transit-time Clamp On Ultrasonic Flowmeter TF1100-EP

    The clamp-on ultrasonic transducers (sensors) are mounted on the external surface of the pipe for non-invasive and non-intrusive flow measurement of liquid and liquefied gasses in fully filled pipe. Two pairs of transducers are sufficient to cover the most common pipe diameter ranges. In addition, its optional thermal energy measurement capability makes it possible to carry out a complete analysis of thermal energy usage in any facility.

     

    This flexible and easy to use flow meter is the ideal tool for the support of service and maintenance activities. It can also be used for the control or even for the temporary replacement of permanently installed meters.

  • Handheld Transit-time Ultrasonic Flowmeter TF1100-CH

    Handheld Transit-time Ultrasonic Flowmeter TF1100-CH

    TF1100-CH Handheld Ultrasonic Flow Meter works on the transit-time method. The clamp-on ultrasonic transducers (sensors) are mounted on the external surface of the pipe for non-invasive and non-intrusive flow measurement of liquid and liquefied gasses in fully filled pipe. Three pairs of transducers are sufficient to cover the most common pipe diameter ranges.

    User can use hand to hold as well as to operate the flow meter main unit. This flexible and easy to use flow meter is the ideal tool for the support of service and maintenance activities. It can also be used for the control or even for the temporary replacement of permanently installed meters.

  • Dual-channel Transit-Time Clamp On Ultrasonic Flowmeter TF1100-DC

    Dual-channel Transit-Time Clamp On Ultrasonic Flowmeter TF1100-DC

    TF1100-DC Dual-channel Wall-mounted Transit Time Ultrasonic Flowmeter works on the transit-time method. The clamp-on ultrasonic transducers (sensors) are mounted on the external surface of the pipe for non-invasive and non-intrusive flow measurement of liquid and liquefied gasses in fully filled pipe. Two pairs of transducers are sufficient to cover the most common pipe diameter ranges. In addition, its optional thermal energy measurement capability makes it possible to carry out a complete analysis of thermal energy usage in any facility.

    This flexible and easy to use flow meter is the ideal tool for the support of service and maintenance activities. It can also be used for the control or even for the temporary replacement of permanently installed meters.

  • Insertion type dual channels ultrasonic flowmeter TF1100-DI

    Insertion type dual channels ultrasonic flowmeter TF1100-DI

    TF1100-DI Dual-channel Insertion Transit Time Ultrasonic Flowmeter works on the transit-time method. It is ok to measure all kinds of liquids in fully filled pipe.The Insertion ultrasonic transducers (sensors) is hot-tapped mounting, there is no ultrasonic compound and coupling problem; Even though the transducers are inserted into pipe wall, they do not intrude into the flow, thus, do not generate disturbance or pressure drop to the flow. The insertion (wetted) type has the advantage of long-term stability and better accuracy. Two pairs of transducers are sufficient to cover the most common pipe diameter ranges. In addition, its optional thermal energy measurement capability makes it possible to carry out a complete analysis of thermal energy usage in any facility.

    This flexible and easy to use flow meter is the ideal tool for the support of service and maintenance activities. It can also be used for the control or even for the temporary replacement of permanently installed meters.

  • TF1100-FI Four-Channel Insertion Transit-Time Ultrasonic Flowmeter

    TF1100-FI Four-Channel Insertion Transit-Time Ultrasonic Flowmeter

    TF1100-FI Four Channels Insertion Transit Time Ultrasonic Flowmeter works on the transit-time method. It is ok to measure all kinds of liquids in fully filled pipe.The Insertion ultrasonic transducers (sensors) is hot-tapped mounting, there is no ultrasonic compound and coupling problem; Even though the transducers are inserted into pipe wall, they do not intrude into the flow, thus, do not generate disturbance or pressure drop to the flow. The insertion (wetted) type has the advantage of long-term stability and better accuracy. Two pairs of transducers are sufficient to cover the most common pipe diameter ranges. In addition, its optional thermal energy measurement capability makes it possible to carry out a complete analysis of thermal energy usage in any facility.

    This flexible and easy to use flow meter is the ideal tool for the support of service and maintenance activities. It can also be used for the control or even for the temporary replacement of permanently installed meters.

  • Portable Dual Channels Clamp On Ultrasonic Flowmeter TF1100-DP

    Portable Dual Channels Clamp On Ultrasonic Flowmeter TF1100-DP

    The clamp-on ultrasonic transducers (sensors) are mounted on the external surface of the pipe for non-invasive and non-intrusive flow measurement of liquid and liquefied gasses in fully filled pipe. Two pairs of transducers are sufficient to cover the most common pipe diameter ranges. In addition, its optional thermal energy measurement capability makes it possible to carry out a complete analysis of thermal energy usage in any facility.

     

    This flexible and easy to use flow meter is the ideal tool for the support of service and maintenance activities. It can also be used for the control or even for the temporary replacement of permanently installed meters.

  • Transit-Time Multi-channel Insertion Ultrasonic Flowmeter TF1100-MI

    Transit-Time Multi-channel Insertion Ultrasonic Flowmeter TF1100-MI

    1. Works on the multi-channel transit-time principle. The accuracy is 0.5%.
    2. Wide bi-directional Flow range of 0.01 m/s to 12 m/s. Repeatability is less than 0.15%.
    3. Low starting flow, super wide turndown ratio Q3: Q1 as 400:1.
    4. 3.6V 76Ah battery power supply, with lifetime over 10 years (measuring cycle: 500ms).
    5. With storage function. Can storage both forward flow and backflow data 10 years (day, month, year ).
    6. Hot-tapped installation, no pipe line flow interrupted.
    7. Standard output is RS485 modbus, Pulse, NB-IoT, 4G, GPRS, GSM can be optional.
    8. Two channels and four channels can be optional.